How can I update the SmartNode 1xxx /2xxx in bootloader mode ?
Posted by Elena Brambilla, Last modified by Daniel Lizaola on 22 November 2017 03:57 PM

 If a firmware update fails the SmartNode will enter the bootloader mode. You can access the SmartNode ONLY with ethernet on the last known ip-address. The username is "admin" and the password "inalp".

After successful login you can download the new firmware with these commands:

  1. sd 1--> enter the download agent
  2. ssip (ip-address) --> replace (ip-address) with the ip-address of your tftp-server. eg. 192.168.1.100
  3. download (path) b --> replace (path) with the path (if necessary). Please note the space and the letter b !
  4. boot --> boots the SmartNode with the new firmware.