Do you have an MRTG script for the the box temperature on the 2960 or 2996?
Posted by Bob Puckett, Last modified by Daniel Lizaola on 20 December 2017 01:08 PM
|
Box Temperature Example:
## Temperature for 2996 Site 1.2.3.4 WriteExpires: Yes Timezone[29xxTemp]: GMT+5 Target[29xxTemp]:1.3.6.1.4.1.1768.20.1.31.0&1.3.6.1.4.1.1768.20.1.31.0:monitor@1.2.3.4 Title[29xxTemp]: 1.2.3.4 Box Temperature PageTop[29xxTemp]: 2996 Box Temperature MaxBytes[29xxTemp]:90 AbsMax[29xxTemp]:90 Options[29xxTemp]: growright, nopercent, integer,absolute, gauge Ylegend[29xxTemp]: Temp C ShortLegend[29xxTemp]: Degrees -C Unscaled[29xxTemp]: dwmy Legend1[29xxTemp]:Current Temp Legend2[29xxTemp]:Current Temp Legend3[29xxTemp]: 5 Min Average Temp Legend4[29xxTemp]: 5 Min Average Temp
|
(8760 vote(s))