Configure Patton SmartNodes with 3CX v20
(FXO and PRI)
Step 1: Create a “VoIP Gateway trunk” on 3CX
- From the Admin panel, click on“Voice & Chat” and then on “Add Gateway”.
- Specify a name.
- Enter the gateway’s “Main Trunk Number”.
- In “Registrar/Server”enter the SmartNode’s IP address.
- Set the "Default Route".
- Take note of the Authentication ID and password
- Click on the “Options” tab and enter the “Number of sim calls per trunk” for this gateway. (This must not exceed the number of lines the gateway supports, e.g. a T1 gateway supports 23 lines.)
- Click “Save” and the gateway is now configured in 3CX.
- The last step is to create an Outbound Rule for this gateway. Once complete, click “Save”.
Step 2: Configure your SmartNode with 3CX
- Run the configuration WEB WIZARD for your SmartNode device and fill in the required information.
- Trinity FXO WEB WIZARD
- Fill in the following tabs of the web wizard
- Device Management Tab
- Here you can change the default admin password.
- Network Settings Tab
- Set the IP address as either DHCP client or a Static address.
- FXO Port Settings Tab
- Select the number of FXO ports (1-8)
- Select the country tone-set profile (United States and Europe)
- 3CX SIP Settings Tab
- Server IP Address: Enter the IP/FQDN of 3CX
- Set the Authentication ID and Password (This was previously configured in 3CX for this gateway)
- Once everything is filled out, you can select “Save” and the config file will be downloaded.
- ISDN WEB WIZARD
- Fill in the following tabs of the web wizard
- Device Management Tab
- Here you can change the default admin password.
- Network Settings Tab
- Set the IP address as either DHCP client or a Static address.
- ISDN Port Settings Tab
- Select the number of ISDN ports (1-4)
- Select the PRI Line Type (E1 or T1)
- Select what the ISDN port is connecting to (PBX or PSTN)
- Select the country tone-set profile (United States and Europe)
- 3CX SIP Settings Tab
- Server IP Address: Enter the IP/FQDN of 3CX
- Set the Authentication ID and Password (This was previously configured in 3CX for this gateway)
- Once everything is filled out, you can select “Save” and the config file will be downloaded.
- Load in Config File
- Enter the IP Address of the SmartNode into a web browser
- Login using the default username and password of admin/<no password>
- Click the top left-hand menu and navigate to “System/Configuration Files” and click the “+” button
- Browse to the file generate and import in as the “startup-config” and click OK
- Reboot the unit without saving
The unit should boot up and register to 3CX to make a receive calls.
|