Onsite/CopperLink/Ethernet Extenders MTU Sizes
Posted by Danny Staub on 05 February 2020 03:07 PM
|
- Standard Ethernet v2 MTU is 1500 bytes; this is the largest payload size of the Ethernet frame and would be the maximum size of e.g. an IP datagram within the Ethernet frame.
- Ethernet v2 frame size with 1500 byte payload is 1518 bytes (without VLAN tags); the Ethernet frame size should not be confused with the MTU.
MTU sizesper Product:
Product
|
max MTU size
|
1069; CL1214 (2174), CL1211, CL1212
|
1518
|
3088A/I; CL1314
|
1504
|
3202; 2160
|
1774
|
OS3301; CL2301
|
1518
|
|
(8763 vote(s))