Configuration description
It is possible to store call logs with quality information in the local aaa data sink. To do so, a service aaa is needed where the calls are routed through. Create a profile aaa with the method local. Then create a service aaa to route the calls through. To see the collected logs use the command show accounting or use the Web-GUI to see the logs. In the Web-GUI, go to the 'Reports' page and select “Call Quality Log” in the tab bar on top of the page. On that page, you will also have the option to export the log as a comma separated text file. The maximum amount of records to be stored on the SmartNode is 50 entries.
The output looks like this:
172.16.71.10(port)[bri]#show accounting AAA Log ======= Call --------- General Start time: 70-02-11 00:01:01 Duration: 21 State: T:16 (originator) Calling party Number : Name : IP Address : 0.0.0.0 CODEC : MOS : 450 Octets Rx/Tx : 0/0 Packets Rx/Tx : 0/0 Lost Packets Rx/Tx : 0/0 Jitter Rx/Tx : 0/0 RTT : 0 Called party Number : Name : IP Address : 172.16.90.3 CODEC : G.711 A-law MOS : 440 Octets Rx/Tx : 0/145280 Packets Rx/Tx : 0/908 Lost Packets Rx/Tx : 0/0 Jitter Rx/Tx : 0/0 RTT : 0
Command sequence to copy, edit and paste in the following link.
example configuration aaa
|