  • Standard Ethernet v2 MTU is 1500 bytes;  this is the largest payload size of the Ethernet frame and would be the maximum size of e.g. an IP datagram within the Ethernet frame.
  • Ethernet v2 frame size with 1500 byte payload is 1518 bytes (without VLAN tags); the Ethernet frame size should not be confused with the MTU.

 

MTU sizesper Product: 

Product

max MTU size

1069; CL1214 (2174), CL1211, CL1212

1518

3088A/I; CL1314

1504

3202; 2160

1774

OS3301; CL2301

1518

 