Configuration Description

Port and context ip configuration for a PPP connection over a V.35 or X21 serial link. The transmit-data-on-edge setting depends on the remote modem device.

 

Command Sequence to copy, edit and pate

context ip

  interface IF_WAN
    ipaddress unnumbered | ip-address ip-mask | dhcp
    point-point
    mtu 1500

context ip
  route 0.0.0.0 0.0.0.0 IF_WAN

port serial 0 0
  encapsulation ppp
  hardware-port < x21 | v35 >
  transmit-data-on-edge <positive |negativ>
  bind interface IF_WAN router
  no shutdown