SmartNode T1 User Port Configuration
Posted by , Last modified by Daniel Lizaola on 14 December 2017 04:51 PM

Configuration Description

2300/2400 T1 Card in Slot 3 0 User-Side DD

 

Command Sequence to copy, edit and paste

configure
system
  clock-source internal
exit

context cs switch

  routing-table called-e164 TAB-FROM-SWITCH

  interface isdn IF-SWITCH
    route call dest-table TAB-FROM-SWITCH
exit

port t1 3 0
  clock slave
  encapsulation q921

  q921
    protocol pp
    uni-side user
    encapsulation q931

    q931
      protocol ni2
      uni-side user
      encapsulation cc-isdn
      bind interface IF-SWITCH switch

port t1 3 0
  no shutdown