FXO Port configuration for US and Europe based application
Posted by , Last modified by Daniel Lizaola on 14 December 2017 04:50 PM

Configuration Description

FXO Port configuration. To be used in the US. For Europe usage, just replace "bell" with "etsi".

 

Command Sequence to copy, edit and paste

port fxo 0 0
  use profile fxo us
  caller-id format bell
  encapsulation cc-fxo
  bind interface IF_FX0_00 switch
  no shutdown

port fxo 0 1
  use profile fxo us
  encapsulation cc-fxo
  bind interface IF_FX0_01 switch
  no shutdown

port fxo 0 2
  use profile fxo us
  encapsulation cc-fxo
  bind interface IF_FX0_02 switch
  no shutdown

port fxo 0 3
  use profile fxo us
  encapsulation cc-fxo
  bind interface IF_FX0_03 switch
  no shutdown