Why does the Siemens Hipath PBX not show the Caller-Name with Qsig as signaling protocol
Posted by Elena Brambilla, Last modified by Daniel Lizaola on 14 December 2017 05:37 PM

The only Siemens Qsig Protocol, which is interoperable with the SmartNode products is ISO-QSIG.

You must choose as QSIG version ISO-QSIG.

All other Siemens Qsig versions show restrictions in the supported supplementary services, such as the caller name.

 

On all ISDN SmartNodes SN4xxx, the following QSIG standard is supported.


"ECMA-143" ISO/IEC 11572, ETSI EN 300 172